Tektronix - DPO5034B

Digital Phosphor Oscilloscope 350MHz 5 GS/s, 25M record length.

Performance:

Bandwidth: 350 MHz

Bandwidth limits: 350 MHz, 250 MHz, and 20 MHz

Number of channels: 4

Rise time: 1 ns

Sample rate: 5 GS/s on all four channels

Record length: 25M standard, up to 125 megapoint with MultiView zoom (optional)

Max. waveform capture rate: >250,000 wfms/s with FastAcq acquisition FastFrame segmented memory acquisition mode with up to 290,000 segments and >310,000 waveforms/s capture rate

Standard 10 MΩ passive voltage probes with less than 4 pF capacitive loading and 500 MHz or 1 GHz analog bandwidth

Vertical Resolution: >11 bits using HiRes sampling

User-selectable bandwidth limit and DSP filters for lower noise and better measurement accuracy

Analysis features:

Wave inspector controls provide easy navigation and automated search of waveform data

Suite of advanced triggers, with standard visual trigger and search

53 automated measurements, selectable filtering, waveform math and FFT analysis

Waveform histogram, eye diagram, TIE (jitter/timing) measurement and analysis

User-definable math using MATLAB, Visual Studio and Excel

Optional analysis for memory, advanced jitter, serial data, power and wideband RF

Protocol features:

Trigger and decode options for mid-speed (100 Mb/s to 1 Gb/s) buses

Trigger and decode options for low-speed (<10 Mb/s) buses

Compliance test options for USB2.0, Ethernet, USB power, MOST, BroadR-Reach

Mask testing on communication, computing and video standards

Mixed signal design and analysis (MSO Series):

16 digital channels (user upgradeable)

MagniVu high-speed acquisition provides 60.6 ps timing resolution on all digital channels

Automated triggering, decode, and search on parallel buses

Per-channel threshold settings

€ 5 995 (net) $7 194 (US)