S-Parameter Test Set 100kHz - 200MHz, 75Ohm
Frequency range: 100 kHz to 200 MHz
Test port impedance: 75 ohms
Directivity: >40 dB
Frequency response:
Transmission (S21, S12): +/- 1 dB
Reflection (S11, S22): +/- 1 dB
Port match:
Test ports 1, 2: >24 dB
Test ports 1, 2 open short ratio: <+/- 1 dB magnitude and <+/- 7.5 degrees phase
Input port: >20 dB return loss
Output ports A, B, and R: > 26 dB
Test port isolation: >100 dB
Insertion loss (RF input to test port 1 or 2): 19 dB typ.
Insertion loss (RF input to output ports A, B, or R): 31 dB typ.
Test port reciprocity:
Transmission (S21, S22): <+/- 0.5 dB magnitude and <+/- 5 degrees phase
Reflection (S11, S22): <+/- 0.5 dB magnitude and <+/- 5 degrees phase
Incident power ratio (test port 1 to test port 2): <+/- 1.5 dB typ.
RF input max. operating level: +25 dBm
RF input damage level: +/- 27 dBm
Port 1 or 2 damage level: +/- 27 dBm
DC bias range: +/- 30 V DC and +/- 20 mA with some degradation of RF specifications typ., 200 mA damage level
Connectors:
Input port and output ports A, B, and R: 50 ohms type -N female
Test ports 1 and 2: 75 ohms type-N female
DC bias inputs: BNC female, rear panel
€ 1.000 (net) $1.200 (US)