Toellner - 8852-64-15

Dual Output Power Supply 2x 0-64 V, 2x 0-2.5 A, 2x 160 W

Option 015 = IEEE 488 Interface

The systemcompatible 8852-64 is a 8850-series dual-output power supply.

Exceptional specifications are achieved with a total output power of 2x160 W

as a result of the classical in-phase control principle.

It deliver voltages up to 2x 64 V and currents 2x 2.5 A. With a resolution of 12 bits in the voltage and current ranges, a simple and convenient user interface, and the excellent specifications, this instrument is suitable for both manual and busbased modes.

A further significant characteristic is the high-resolution measurement of the voltage and current values; these are output on 4-digit LED displays and can be read at a high rate in bus mode.This means that additional measuring instruments are usually superfluous.

The output values are adjusted with a selectable sensitivity using wear-free incremental spinwheels, thus permitting reliable and precise adjustment of the output voltage and current even after many years of service.

Depending on the values set for the voltage and current, the power supply can be operated as a voltage source or a current source depending on the load conditions. All outputs can be connected in parallel or series without problem.

Tracking function:

The automatic tracking mode with dualoutput power supplies means that it is possible to control the output voltage of output 2 as a function (0 % to 100 %) of output 1 with retention of all control properties.

Remote control:

Command syntax in accordance with IEEE 488.2 with command set switchable between compatible TOELLNER commands and SCPI commands.

GPIB interface (option):

Interface connection in accordance with IEEE 488.1; electrically isolated from main outputs. The device address can be set as desired per menu.

Setting rate: approx. 25 settings/s

Measuring rate: approx. 20 measurements/s

RS 232 interface (option):

9-pin D-SUB connector; electrically isolated from the main outputs

Transfer: half-duplex mode, asynchronous; 110 to 19200 baud adjustable permenu.

Setting rate: approx. 20 settings/s

Measuring rate: approx. 15 measurements/s


These modern, proven and exceptionally well equipped power supplies are additionally characterized by supplementary functions such as the saving of 100 instrument settings, the standby circuit for the power outputs, sense and tracking modes.

Operating functions.

Display of voltage and current: On two selectable 4-digit V/A displays for the dual instruments

Constant voltage or constant current mode is indicated by single LEDs

Sense mode can be selected directly. Connection to front or rear of instruments

Nonvolatile memory for 100 complete instrument settings and the last setting when switching-off

Special features:

In-phase regulation, thus extremely low residual ripple, below 300 μVrms (depends on model)

Operation possible as voltage source or current source

Adjustment of voltage and current using wear-free incremental spinwheels

No switch-off peaks and no transients at output

Sensing as standard, Correctable voltage 0.5 V/line

Maximum precision using μP-controlled autocalibration

Extremly high long-term stability

Resistant to continuous load

Extremly quiet

100 complete instrument settings can be saved resistant to power failure

RS 232, GPIB interface optional

Analog interface optional, floating also possible

LabViewTM driver

Electrically isolated outputs

As desktop unit with adjustable feet or for 19“ mou or 19“ adapter for rack mounting

Outputs:

Floating for all models

Electrically isolated in the dual-output power supplies

Series and parallel connections possible

Safety sockets at front

Output 1:

Voltage: 0-64 V

Current: 0-2.5 A

Output 2:

Voltage: 0-64 V

Current: 0-2.5 A

Power:

2x 160 W

Setting resolution:

Voltage: 20 mV

Current: 1 mA

Setting accuracy:

Voltage: 0.1 % + 20 mV Current: 0.2 % + 2 mA

Residual ripple (10 Hz - 1 MHz):

Voltage: 1 mVeff

Current: 100 μAeff

Measuring accuracy:

Voltage: 0.1 % + 40 mV

Current: 0.2 % + 2 mA