Dual Range AC Current Clamp, Nominal current range: 20A, 200A, Frequency range: 40Hz-10kHz.
The i200s is a dual range 20A and 200A ac current clamp with voltage output via a safety insulated BNC connector. A dual banana to BNC adapter is supplied to allow the i200s to be connected to multimeters with banana inputs.
Included adapter for DMM's or ScopeMeters serie 120
Two ranges: 20 A & 200 A, 10 or 100 mV/ Amp output
Take accurate current readings without breaking the circuit
Max. conductor Ø 20 mm
CAT III 600V safety rating
Nominal current range: 20 A, 200 A
Continuous current range: 0.1 A - 24 A, 0.5 A - 200 A
Maximum Non-Destructive Current: 240 A
Lowest measurable current: 0.1 A
Basic Accuracy: 1.5% +0.5 A (48-65 Hz)
Useable frequency: 40 Hz - 10 kHz
Output level(s): 100 mV/A 10 mV/A
€ 295 (net) $354 (US)